Novel implants and improved surgical techniques have made reconstruction of the radial head with open reduction and internal fixation possible in most cases. Radial head replacement recovery time things you didnt know. The humeral head size can be estimated by overlaying the head templates over the contralateral humeral head. Although text books refer to the triceps tendon, the. Listing a study does not mean it has been evaluated by the u. Break of radius head, not reconstuctable break manson iii, iv. A novel method for the control of a myoelectric upper limb prosthesis was. Hcp content posted june 19, 2015 in animated demonstrations and zimmer biomet extremities.
It is not to be redistributed, duplicated or disclosed without the. Thus, access needs to be made that will allow the proximal radius to be mobilised. The authors propose a novel surgical technique for complex fractures of the elbow necessitating a radial head arthroplasty rha that spares additional soft tissue morbidity and allows. Depuy synthes elbow recall lawsuit elbow replacement lawyers. Preparation of the radial canal the 16mm radial reamer is introduced into the radial canal, seated and twisted. Implant function is directly related to accurate surgical technique. Surgical approach the aim is to remove the damaged radial head fragments and gain sufficient access to insert the implant. Week 1 begin elbow active rom and activeassisted rom. Novel implants and improved surgical techniques have made reconstruction of the radial head.
The treatment of complex radial head fractures remains a challenge for the orthopedic surgeon. Figure 2 it is important to note that the m2amagnum acetabular component is a hemispherical design. Kocher recommended a j shaped skin incision from the lateral supracondylar ridge to the subcutaneous ulna. Biomet sports medicine is not responsible for selection of the appropriate surgical technique to be utilized for an individual patient. A modular prostheses system for replacement of the radial head portion of the radius bone, and methods for its use are disclosed. The system comprises a stem component comprising a anchoring portion and a mounting portion, and a head component having an open channel wherein the open channel is configured to connect to the mounting portion along an assembly axis that is. Hcp contentposted june 19, 2015 in animated demonstrations and zimmer biomet extremities. Learn more about the explor modular radial head from zimmer biomet. Radius head prothesis surgical technic biotech oldal 1 fk radius head modular prothesys surgical technique 1.
Radial head resection versus arthroplasty in unrepairable. The surgeon who performs any implant procedure is responsible for determining and utilising the appropriate techniques for implanting the prosthesis in each particular patient. The innovative cutthrough femoral trials provide surgeons with the flexibility to choose their preferred surgical approach to maximize efficiency. The radial cutting jig is placed over the neck of the radius and the radial head is resected leaving a flat surface, so the contact between the collar of the prosthesis and the bone is complete. Radius head prothesis surgical technic biotechmedical.
Even if the radial head fixation is the preferred technique in every. Radial head fractures often occur in association with other elbow fractures and softtissue injuries. Degenerative or posttraumatic disabilities presenting pain, crepitation, and decreased motion at the radiohumeral andor proximal radioulnar joint with. Surgical technique is a critical variable in the success of any arthroplasty. Transolecranon surgical approach for radial head arthroplasty. Pdf radial head arthroplasty has joined the armamentarium of options for the treatment of complex. Although this is a retrospective study, the high complication rate occurring after radial head replacement in comparison with radial head resection, as well as good functional results obtained with this last technique, leads us to recommend it for comminuted radial head fractures without associated instability. The surgeon who performs any implant procedure is responsible for determining and utilizing the appropriate techniques for implanting prosthesis in each individual. Radial head fractures are the most common fracture around the elbow, with an incidence of 30 per 100,000 persons per year, accounting for 1% to 5% of all long bone fractures and 20% of proximal. Radial head prosthesis surgical technique depuy synthes 5 indications the depuy synthes radial head prosthesis system is indicated for primary replacement of the radial head after. This technique was prepared in conjunction with the vanguard xp total knee developing surgeons.
Different types of fractures should choose different surgical methods according to their characters. This material is intended for the sole use and bene. For simple radial head replacement, see modified posterior approach wrightington. L2l radial head system surgical technique zimmer biomet. Comprehensive total shoulder system versadial humeral heads infinite offset options between 0. Biomet, as the manufacturer of this device, does not practice medicine and does not recommend this or any other surgical technique for use on a specific patient. Biomet is not responsible for selection of the appropriate orthopaedic implant or surgical technique, nor does it advocate a particular technique to be utilised on an individual patient. Radial head replacement is indicated for irreparable radial head fractures associated with elbow instability. Biomet uk ltd, is not responsible for selection of the appropriate surgical technique to be utilised on an individual patient. This treatment of complex radial head fractures has recently improved because of longterm followup studies, increased biomechanical research on elbow stability, and improved surgical techniques.
Surgical approach and incision of the annular ligament 4. Modular radial head prostheses biomet manufacturing corp. With an open line of communication between the surgeon and the therapist, an appropriate therapy plan can be initiated to protect both simple and. Lateral resurfacing elbow lre cambridge orthopaedics. This data collection effort will document the clinical outcomes of the radial head. The design is based upon the phase 2 but is available in 5 sizes to provide a better. Modular radial head surgical technique in cases of mason type 3 or 4, revision of excision, or an inability to plate. There will be no experimental or investigational surgical techniques used. Cohort 2 received biomet explor radial head replacement.
Genesis ii instrumentation has been developed to be an. Biomet uk ltd, as the manufacturer of this device, does not practice medicine and does not recommend any particular surgical technique for use on a specific patient. Radial head prostheses rhp have been developed to decrease the complications rate following a radial head resection surgery. L2l radial head is designed with a smooth stem to be implanted intentionally linetoline. The authors propose a novel surgical technique for complex fractures of the elbow necessitating a radial head arthroplasty rha that spares additional soft tissue morbidity and allows for accurate sizing of the radial head. Surgical technique distal cut first surgical technique. There are 24 different heads and 10 different stems, providing surgeons with a. Modular revision hip system product information and. Expose the radial capitellar joint using the kocher approach through the interval between the anconeus and extensor carpi ulnaris muscles. However, extremely comminuted radial head fractures with associated instabilities still require replacement of the radial head with a. Surgical techniques and patient care are to be standard for the surgeon participating in the protocol. The indications for use of radial head replacement. When one surgeon connects with one patient to provide personalized care, the promise of medicine is fulfilled. Explor modular radial head surgical technique zimmer biomet.
For more extensive exposure of elbow consider global approach using kocher interval. Explor modular radial head data collection full text. Oxford unicompartmental knee manual of the surgical. Radial head fracturesadvanced techniques in surgical. Biomet is not responsible for selection of the appropriate surgical technique to be utilized for an individual patient. Fractures of the radial head first were described in 1905 and were generally treated by immobilization. Hutchinson on radial head replacement recovery time. A second check in proper placement of the stem is performed by overlaying the head and stem together at the appropriate position within the humeral canal. Biomet deutschland gmbh, as the manufacturer of this device, does not practice medicine and does not recommend any particular orthopaedic implant or surgical technique for use on a specific patient.
The treating surgeon is responsible for determining the appropriate treatment, techniques, and products for each individual patient. Surgical technique and clinical experience article in journal of orthopaedic trauma 2110. Concractura, which inhibit pronation and supination movement, caused by former deformity, or break which is caused by radius head missing. Lawyers are filing lawsuits on the depuy synthes radial head prosthesis system. The l2l radial heads simple design is intended to provide fit and comfort for the patient, and ease of implantation for the surgeon. Radial head arthroplasty modern implants unipolar or bipolar, monoblock or modular, anatomical or nonanatomical, cemented or pressfit correct diameter, height, medial offset and cervicocephalic angle bipolarity permits an automatic positioning of the radial head with respect to the neck and the opposite. Because of heterogeneity in level of evidence, surgical technique. The aim of the rhp is to replicate the physiological radiocapitellar tracking, reproducing the mechanical function of the native radial head. This material is intended for health care professionals and the biomet sales force. Explor radial head plating system surgical technique.
For example, a size 5 stem will utilize a size 5 reamer with. Low profile fixation of radial head and neck fractures. Once the femoral head has been resected, it is possible to commence acetabular preparation. Anatomical alignment is critical to the success of.
1226 742 1393 830 1206 384 845 416 903 895 852 849 1411 831 455 994 1322 438 1098 87 473 65 217 1043 1429 31 1231 1405 80 139 1402 188 699 1139 534 126 1365 1027 183 1182 932 1064 1394 501